Measurement of gap between abutment and fixture in dental conical connection implants. A focused ion beam SEM observation

2020

Background The aim of the authors was to examine the abutment-fixture interface in Morse-type conical implants in order to verify gaps at this level using a new microscopical approach. Material and Methods In this in vitro study, 20 abutment-fixture complexes were prepared by sectioning (longitudinal and cross-sectional to the long axis) with a microtome and then with a focused ion beam (FIB). This is a micrometric machine tool that uses gallium ions to abrade circumscribed areas to dig deeper into the cuts obtained with the microtome in order to eliminate cut-induced artifacts. This is because the FIB abrasion is practically free from artifacts, which are normally generated by the action o…

Dental Stress Analysisbusiness.product_categoryMaterials scienceScanning electron microscopemicrobial leakageDental AbutmentsFixtureFocused ion beamAbrasion (geology)law.inventionSettore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE03 medical and health sciences0302 clinical medicineOpticslawfocused ion beam SEMMaterials TestingMicrotomeimplant-abutment connectionGeneral DentistryDental ImplantDental Implantsbusiness.industryResearchmorse taperDental Implant-Abutment Design030206 dentistryConical surface:CIENCIAS MÉDICAS [UNESCO]Machine toolCross-Sectional StudiesOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASdental abutmentSurgerybusinessAbutment (dentistry)Implantology
researchProduct

Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit

2020

Background: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutments under different insertion torque loads. Materials and Methods: A total of 120 implants were used, 60 with external connection (EC) and 60 with Morse taper connection (IC). Straight (SA) (n = 60) and angulated abutments (AA) (n = 60) were randomly screwed to each connection at different torque levels (n = 10 each): 10, 20 and 30 Ncm. All specimens were subjected to thermal and cyclic loading …

Insertion torqueabutmentAbutmentlcsh:Medicine02 engineering and technologyArticle03 medical and health sciencesinternal connection0302 clinical medicineMedicineTorqueexternal connectionExternal connectionimplant-abutment interfaceMorse taperbusiness.industrylcsh:R030206 dentistryGeneral MedicineStructural engineering021001 nanoscience & nanotechnologyConnection (mathematics)misfitImplant0210 nano-technologybusinessImplant abutmentJournal of Clinical Medicine
researchProduct

Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review

2017

Background To carry out a systematic literature review of the causes of preload loss of the abutment screws, of internal and external connection implants, tightened to different torque values and subjected to cyclic loading. Material and methods A systematic search was conducted in PubMed, EMBASE, and Cochrane Library databases with reference to in vitro studies in which internal and external connection implants were subjected to cyclic loads to determine the degree of loosening of the abutment screws after loading. Results The reviewed studies tested distinct implant connections (mostly externally hexed, and morse taper) subjected to diverse cycles (from 16667 to 1 million), with loads ran…

OrthodonticsProsthetic DentistryMaterials scienceSingle implant030206 dentistryReview:CIENCIAS MÉDICAS [UNESCO]03 medical and health sciencesPreload0302 clinical medicineScrew looseningUNESCO::CIENCIAS MÉDICASCyclic loading030212 general & internal medicineImplantGeneral DentistryMorse taperAbutment (dentistry)Systematic search